TR-1 Emergency Power Systems (Generators)

$1,500.00

Calculated total $1,500.00

SKU: EZTR1-P0046 Category:

Plan your TR-1 emergency power inspection

Arrange a TR-1 inspection for emergency power systems and generators in New York City. Use this page to understand the scope, prepare project records, and get your inspection configured with AKS Architectural & Engineering Services, LLP.

What this inspection covers

The inspection supports review of emergency power system work, including generator-related installations and unusual materials, systems, or design applications that may require special inspection under BC 1704.13. Project-specific scope depends on the approved plans, filing, equipment, and work performed.

Records to have ready

  • Approved drawings, specifications, and the relevant DOB filing or permit information.
  • Generator and emergency-power equipment schedules, manufacturer installation instructions, and fuel-system details.
  • Previous inspection records, sign-on, inspection, and sign-off information, plus the site contact who can provide access.

Before the inspector arrives

  • Make the generator and associated emergency-power components safely accessible.
  • Ensure the work area is ready for observation and that required components are installed as shown in the approved documents.
  • Confirm a site contact can coordinate access and provide the records.
  • Keep project-specific questions ready; AKS will confirm what is needed for the filing and inspection scope.

Configure your inspection online

Use the inspection configurator on this page to start the TR-1 emergency power systems (generators) service. If the project is too large or complex for menu pricing, request a custom quote and share the project details with AKS.

Code references

1704.13 Special case. Special inspections shall be required for proposed work that is, in the opinion of the commissioner, unusual in its nature, such as, but not limited to, the following examples:
•Construction materials and systems that are alternatives to materials and systems prescribed by this code.
•Unusual design applications of materials described in this code.
•Materials and systems required to be installed in accordance with additional manufacturer’s instructions that prescribe requirements not contained in this code or in standards referenced by this code.

SECTION BC 2702 EMERGENCY POWER SYSTEMS
2702.1 Installation. Emergency systems shall be installed in accordance with the New York City Electrical Code, NFPA 110 and NFPA 111, and shall have an on-premises fuel supply sufficient for not less than 6-hour full-demand operation of the system. However, for R-2 occupancies required to provide emergency power systems pursuant to the provisions of Section 403.11.2, and for voluntarily installed emergency power systems, natural gas from the public utility street main shall be permitted as fuel supply.

Details

Project Too Big Or Complex For Menu Pricing? Contact Us For A Detailed Project Specific Proposal.

Not every project fits our online catalog. Share your project details, and our team will review your requirements, recommend the right inspection services, and provide a custom quote.

Request a Custom Quote